Tantalum Fasteners

Tantalum Fasteners

Tantalum fasteners are best known for its unmatched corrosion resistance and chemical inertness. Tantalum fasteners have a similar corrosion resistance to that of glass, but all of the typical mechanical and electrical properties of a metal.
Tantalum fasteners are also extremely stable at high temperatures, since tantalum has a melting point around 3000°C. High temperature applications require vaccum or inert gas since tantalum may embrittle when used in oxygen rich environments above 250°C. Tantalum fasteners are also one of the most bio-compatible metals available and is also radio-opaque due to its high density (16.68 g/cm3).
All tantalum fasteners are available in commercially pure tantalum and tantalum 2.5% tungsten (Ta-2.5%W).
  • Tantalum Fasteners
  • Tantalum Fasteners
  • Tantalum Fasteners
  • Tantalum Fasteners
  • Tantalum Fasteners
  • Tantalum Fasteners
  • Tantalum Fasteners
  • Tantalum Fasteners
  • Tantalum Fasteners

RAYCHIN SPECIALTY METALS FASTENERS: BOLTS, NUTS, SCREWS, WASHERS, STUDS, THREADED RODS, U-BOLT, J-BOLTS

STANDARD AND CUSTOMIZED, SMALL BATCH AND LARGE BATCH, IMPERIAL AND METRIC


  • Immune to numerous acids and chemicals 

  • Better corrosion resistance than nickel alloys, titanium or zirconium

  • High strength and stiffness in vacuum and inert gas up to 2000°C (3600°F)

  • Can become brittle when used in oxygen above 300°C

  • High purity and biocompatibilty

Request a Quote from RAYCHIN

We're here to help!

Request a Quote



Tantalum Fasteners: Ultra‑High Performance Refractory Metal Fasteners for Extreme Environments

Pure Tantalum (R05200 / R05400 / ASTM F560) | Tantalum Alloys (Ta2.5W, Ta10W) | UNS R05200 · R05400 · ASTM B365 · B708 · NACE MR0175

RAYCHIN LIMITED is a world‑leading manufacturer of Tantalum fasteners – a comprehensive range of precision fasteners produced from pure tantalum and tantalum alloys. Tantalum is a rare, refractory metal with exceptional corrosion resistance, a melting point of 2996°C, and outstanding biocompatibility. These properties make tantalum fasteners the ultimate choice for the most demanding applications in chemical processing, aerospace, medical implants, semiconductor manufacturing, and nuclear industries. Our product line encompasses all major fastener types including Tantalum bolts, Tantalum nuts, Tantalum screws, Tantalum washers, Tantalum stud bolts, and Tantalum threaded rods – all manufactured to the highest precision standards. Tantalum is virtually inert to attack by most acids, including hydrochloric acid, nitric acid, and aqua regia, below 150°C. It forms a stable, protective oxide layer (Ta2O5) that provides exceptional corrosion resistance. Our portfolio includes all standard and custom configurations manufactured to NAS, AN, MS, ANSI, ASTM, ASME, SAE, API, NACE, ISO, DIN and KS standards. Whether you require Tantalum fasteners for chemical reactors, medical devices, high‑temperature vacuum furnaces, or critical aerospace assemblies, RAYCHIN delivers precision, quality, and full traceability. All mechanical properties are presented in MPa and ksi.

tantalum fastenerstantalum boltstantalum nutstantalum screwstantalum washerstantalum stud boltstantalum threaded rodsR05200 fastenersR05400 fastenersASTM F560 fastenersrefractory metal fastenerscorrosion resistant fastenerstantalum hex boltstantalum socket head screwstantalum heavy hex nutstantalum flat washers

Tantalum Fasteners – Complete Product Range

Tantalum Bolts

Tantalum bolts include hex head bolts, heavy hex bolts, socket head cap bolts, flange bolts, and carriage bolts. Available in inch series per ASME B18.2.1 and metric series per ISO 4014/4017 / DIN 931/933. Diameters from M3 to M64 (#0 to 2½"). Ideal for extreme corrosion environments such as chemical reactors, pickling equipment, and pharmaceutical processing vessels. Tantalum bolts maintain structural integrity up to 2000°C in inert atmospheres and resist all common acids except hydrofluoric acid. Ta10W alloy bolts offer increased strength for elevated temperature applications.

Tantalum Nuts

Tantalum nuts manufactured in all configurations: hex nuts, heavy hex nuts, jam nuts, slotted nuts, coupling nuts, and flange nuts. Available per ASME B18.2.2, ISO 4032, DIN 934. Thread classes 2B, 6H. Matching nuts for tantalum stud bolts and threaded rods. Nuts can be supplied with various finishes including passivation to enhance the protective oxide layer. Tantalum nuts are non‑magnetic and remain stable in aggressive chemical environments, making them ideal for medical implant assemblies and semiconductor processing equipment.

Tantalum Screws

Tantalum screws include socket set screws, socket cap screws, flat head screws, button head screws, and machine screws. Precision hexagon socket drives per ASME B18.3 and ISO 4762. Set screws available with cup, cone, flat, and dog points per ISO 4026-4029. Widely used in medical implants (bone fixation, cranial plates), laboratory instrumentation, and high‑purity chemical systems where metallic contamination must be avoided. Tantalum's biocompatibility and radiographic visibility make it the material of choice for surgical implants.

Tantalum Washers

Tantalum washers produced in all types: flat washers (plain), spring washers, lock washers, Belleville washers, and custom shapes. Available in inch (ASME B18.22.1) and metric (ISO 7089, DIN 125) series. Tantalum washers provide excellent corrosion resistance and maintain spring properties at elevated temperatures. Used in high‑temperature vacuum furnaces, chemical processing equipment, and aerospace assemblies where reliability in extreme environments is critical. Can be supplied in annealed or stress‑relieved conditions.

Tantalum Stud Bolts

Tantalum stud bolts (fully threaded studs) and double-end studs offered with two heavy hex nuts (if required) per ASME B16.5 / B16.47. Manufactured to ASTM B365 / B708 specifications. Available in all diameters with thread lengths per customer specification. Extensively used in high‑pressure chemical reactors, heat exchangers, and pressure vessel closures in the chemical processing and pharmaceutical industries. Tantalum stud bolts resist attack from boiling hydrochloric acid, sulfuric acid, and other aggressive media where stainless steel and even titanium fail.

Tantalum Threaded Rods

Tantalum threaded rods (fully threaded bars) available in continuous thread, full thread, and custom lengths up to 3 meters. Manufactured to ASTM B365 / B708. Diameters from M3 to M48. Ideal for applications requiring long lengths of corrosion‑resistant threaded material, including chemical plant supports, immersion heater assemblies, and semiconductor processing equipment. Tantalum threaded rods maintain their integrity in oxidizing and reducing environments and can be used at cryogenic temperatures as well as elevated temperatures.

Critical Applications of Tantalum Fasteners

Chemical Processing

Tantalum fasteners are extensively used in chemical reactors, heat exchangers, distillation columns, and piping systems handling aggressive media such as hydrochloric acid, sulfuric acid, nitric acid, phosphoric acid, and bromine. Tantalum is virtually inert to all acids except hydrofluoric acid and hot concentrated sulfuric acid above 150°C. Tantalum bolts and stud bolts provide reliable fastening in equipment where even high‑nickel alloys fail. Used in chlor‑alkali plants, pharmaceutical synthesis, and specialty chemical manufacturing.

Aerospace & Defense

Tantalum fasteners in rocket nozzles, jet engine components, missile guidance systems, and satellite assemblies. Tantalum's high melting point (2996°C), excellent high‑temperature strength, and resistance to thermal shock make it ideal for extreme environments. Tantalum screws and bolts are used in combustion chambers, exhaust nozzles, and heat shields where temperatures exceed 1500°C. Tantalum‑tungsten alloys (Ta10W) offer enhanced strength for the most demanding aerospace applications.

Medical Implants

Tantalum fasteners including screws, nuts, and washers are widely used in orthopedic implants, cranial plates, spinal fixation systems, and dental prosthetics. Tantalum is completely biocompatible, non‑toxic, and not rejected by the human body. It exhibits osseointegration properties, allowing bone tissue to grow into porous tantalum structures. Tantalum is radiographically visible, enabling post‑operative imaging. ASTM F560 (R05200, R05400) specifies the requirements for tantalum used in surgical implant applications.

Semiconductor Manufacturing

Tantalum fasteners in semiconductor processing equipment, including CVD reactors, ion implanters, and sputtering systems. Tantalum's low vapor pressure, high purity, and resistance to corrosive process gases make it essential for critical applications. Tantalum screws and threaded rods are used in wafer handling systems, chamber components, and heater assemblies where metallic contamination cannot be tolerated. High‑purity tantalum (99.95%+) ensures process integrity.

Nuclear Industry

Tantalum fasteners in nuclear fuel processing, waste treatment, and reactor components. Tantalum exhibits excellent resistance to corrosion by molten salts and liquid metals, and maintains its mechanical properties under radiation. Used in spent fuel reprocessing equipment, nuclear waste vitrification vessels, and experimental reactor assemblies. Tantalum's low thermal neutron capture cross-section makes it suitable for certain nuclear applications.

High‑Temperature Vacuum Furnaces

Tantalum fasteners used in vacuum furnace hot zones, heating elements, heat shields, and support structures. Tantalum maintains strength at temperatures exceeding 2000°C in vacuum or inert atmospheres. Tantalum bolts, nuts, and washers secure heating elements and radiation shields in furnaces for sintering, brazing, and heat treating. Tantalum's low vapor pressure ensures no contamination of processed materials.

International Standards & Global Designations – Tantalum Fastener Materials

RAYCHIN LIMITED manufactures Tantalum fasteners from material conforming to the most widely used national and international specifications. All material is traceable to the mill.

AlloyUNSASTM StandardStandards / Specifications (Material only)
Pure Tantalum (EB or VAR)R05200ASTM B365 (Rod/Bar), B708 (Plate/Sheet), F560 (Medical)Electron beam or vacuum arc melted, unalloyed tantalum, low interstitial content
UNS R05200, R05400 (sintered), Werkstoff Nr. 2.0205 (similar)
AMS 7845 (bar), AMS 7846 (sheet/plate)
ASTM F560 (surgical implant applications – R05200, R05400)
ISO 13782 (surgical implants)
DIN 17860 (tantalum semi-finished products)
NACE MR0175 / ISO 15156-3 (sour service – suitable for tantalum)
Tantalum AlloysR05252ASTM B365, B708Ta-2.5W (Tantalum-2.5% Tungsten) – higher strength than pure Ta
R05255ASTM B365, B708Ta-10W (Tantalum-10% Tungsten) – maximum strength, used for springs and high‑temp applications
R05240ASTM B365, B708Ta-40Nb (Tantalum-40% Niobium) – reduced density, good formability
AMS 7847 (Ta-10W bar), AMS 7848 (Ta-10W sheet)
UNS R05200 UNS R05400 ASTM B365 ASTM B708 ASTM F560 AMS 7845 ISO 13782 DIN 17860 Ta2.5W Ta10W NACE MR0175

Chemical Composition (Weight %) – Tantalum Alloys for Fasteners

Our Tantalum fasteners are produced from material conforming to the limits of applicable ASTM, AMS, and ASME standards. High‑purity grades available up to 99.99% (4N).

Pure Tantalum (UNS R05200 / R05400) – ASTM B365 / F560

ElementComposition (R05200 – EB/VAR)Composition (R05400 – Sintered)
Carbon (C)≤ 0.01%≤ 0.01%
Oxygen (O)≤ 0.015%≤ 0.03%
Nitrogen (N)≤ 0.01%≤ 0.01%
Hydrogen (H)≤ 0.0015%≤ 0.0015%
Niobium (Nb)≤ 0.10%≤ 0.10%
Iron (Fe)≤ 0.01%≤ 0.01%
Titanium (Ti)≤ 0.01%≤ 0.01%
Tungsten (W)≤ 0.05%≤ 0.05%
Molybdenum (Mo)≤ 0.02%≤ 0.02%
Silicon (Si)≤ 0.005%≤ 0.005%
Nickel (Ni)≤ 0.01%≤ 0.01%
Tantalum (Ta)Balance (≥99.5%)Balance (≥99.5%)

Tantalum-Tungsten Alloys (Ta2.5W / Ta10W)

ElementTa-2.5W (UNS R05252)Ta-10W (UNS R05255)
Tungsten (W)2.0 – 3.5%9.0 – 11.0%
Carbon (C)≤ 0.01%≤ 0.01%
Oxygen (O)≤ 0.015%≤ 0.015%
Nitrogen (N)≤ 0.01%≤ 0.01%
Hydrogen (H)≤ 0.0015%≤ 0.0015%
Niobium (Nb)≤ 0.10%≤ 0.10%
Iron (Fe)≤ 0.01%≤ 0.01%
Tantalum (Ta)BalanceBalance

Metallurgical note: Tantalum is a body-centered cubic (BCC) refractory metal with a melting point of 2996°C, second only to tungsten and rhenium. It is highly ductile and can be cold worked extensively without intermediate annealing. Tantalum derives its exceptional corrosion resistance from a stable, adherent pentoxide (Ta2O5) film that forms spontaneously in air or oxidizing media. This oxide film is self‑healing if damaged and protects the underlying metal from attack by all common acids except hydrofluoric acid. Tantalum is also completely biocompatible and non‑toxic, making it ideal for medical implants. Tungsten alloying additions (2.5% or 10%) increase strength, creep resistance, and recrystallization temperature while maintaining good fabricability.

Complete Mechanical & Physical Properties – Tantalum Alloys for Fasteners (MPa / ksi)

Tantalum fasteners are supplied in appropriate conditions (annealed, stress relieved, or as‑worked) per ASTM B365 and customer specifications. Data represent typical values based on industry standards.

Pure Tantalum (R05200) – Mechanical Properties

ConditionTensile Strength (MPa)Tensile Strength (ksi)0.2% Yield Strength (MPa)Elongation (%)
Annealed (ASTM B365)≥ 172≥ 25≥ 138≥ 25
Typical Annealed (Bar)205-27530-40165-24025-40
Cold Worked (30%)345-41050-60275-3455-15
Stress Relieved275-34540-50205-27515-25

Tantalum Alloys – Mechanical Properties

Alloy / ConditionTensile Strength (MPa)Tensile Strength (ksi)0.2% Yield Strength (MPa)Elongation (%)
Ta-2.5W (R05252) Annealed310-41045-60240-31020-30
Ta-2.5W Cold Worked450-55065-80410-4805-15
Ta-10W (R05255) Annealed480-62070-90410-52015-25
Ta-10W Cold Worked690-860100-125620-7602-10

High‑Temperature Mechanical Properties – Pure Tantalum (representative)

Test TemperatureTensile Strength (MPa)Tensile Strength (ksi)0.2% Yield Strength (MPa)Elongation (%)
20°C (70°F)2403517035
500°C (932°F)2002911040
1000°C (1832°F)140207045
1500°C (2732°F)6092560
2000°C (3632°F)253.61070

Physical Properties – Tantalum

PropertyPure TantalumTa-10W
Density (g/cm³)16.616.8
Density (lb/in³)0.6000.607
Melting Point (°C)29963025 (approx)
Melting Point (°F)54255475
Elastic Modulus (GPa)186200
Elastic Modulus (ksi)2700029000
Thermal Expansion (20-100°C) μm/m·°C6.56.5
Thermal Conductivity (W/m·K)57.554.0
Electrical Resistivity (nΩ·m)130170
Specific Heat (J/kg·K)140140

High‑Temperature Performance of Tantalum Fasteners

Tantalum is one of the most refractory metals, with a melting point of 2996°C (5425°F), exceeded only by tungsten and rhenium. This exceptional high‑temperature capability makes tantalum fasteners ideal for extreme thermal environments. Tantalum maintains useful mechanical properties at temperatures exceeding 2000°C in vacuum or inert atmospheres. It exhibits excellent creep resistance and thermal stability. Tantalum‑tungsten alloys (Ta-10W) offer significantly higher strength at elevated temperatures and are used for springs, fasteners, and load‑bearing components in high‑temperature furnaces, rocket engines, and jet propulsion systems. Tantalum's low vapor pressure ensures no contamination of vacuum environments, making it essential for vacuum furnace hot zones and semiconductor processing equipment.

Elevated Temperature Capabilities

PropertyPure TantalumTa-2.5WTa-10W
Maximum Service Temperature (vacuum/inert)2400°C (4350°F)2450°C (4440°F)2500°C (4530°F)
Recrystallization Temperature1100-1300°C1300-1500°C1400-1600°C
Oxidation Limit (air)300°C (572°F)*350°C (662°F)*400°C (752°F)*
Creep ResistanceModerateGoodExcellent

*Note: Tantalum oxidizes rapidly in air above 300°C. For high‑temperature air applications, protective coatings are required. Tantalum is primarily used in vacuum, inert gas, or reducing atmospheres at elevated temperatures.

Exceptional Corrosion Resistance of Tantalum Fasteners

Tantalum is renowned for its outstanding corrosion resistance, approaching that of glass in many aggressive media. It is virtually immune to attack by most acids and chemical compounds below 150°C. The protective Ta2O5 oxide film (thickness 2-5 nm) is stable, adherent, and self‑healing if damaged. Tantalum's corrosion resistance often exceeds that of noble metals like platinum at a fraction of the cost.

  • Hydrochloric Acid: Tantalum is completely resistant to hydrochloric acid at all concentrations and temperatures up to 110°C (boiling). Even above 110°C, corrosion rates remain extremely low (0.0004 mm/year at 150°C).
  • Sulfuric Acid: Excellent resistance up to 150°C at all concentrations. At 175°C in concentrated sulfuric acid, corrosion rate is only 0.0004 mm/year. In fuming sulfuric acid (15% SO3) at 130°C, corrosion rate is 15.6 mm/year.
  • Nitric Acid: Completely resistant at all concentrations and temperatures up to boiling.
  • Phosphoric Acid: Excellent resistance up to 150°C. At 250°C in 85% phosphoric acid, corrosion rate is approximately 20 mm/year.
  • Aqua Regia: Completely resistant at all temperatures up to boiling.
  • Organic Acids: Completely resistant to all organic acids, including acetic, formic, and citric acids.
  • Halogens: Resistant to chlorine, bromine, and iodine up to 150°C in dry conditions. Moist halogens can attack tantalum.
  • Alkalis: Tantalum is attacked by strong alkalis. In 40% NaOH at 110°C, dissolution is rapid. In KOH solutions, attack occurs above 100°C.
  • Hydrofluoric Acid: Tantalum is rapidly dissolved by hydrofluoric acid (HF) and by mixtures containing HF (such as HF/HNO3). This is the primary acid that attacks tantalum.
  • Molten Metals: Tantalum is resistant to many molten metals including Li, Na, K, Mg, and U up to 1000°C.

Tantalum's corrosion resistance is superior to that of stainless steels, nickel alloys, titanium, and zirconium in most reducing acid environments. It is the material of choice for critical applications where long‑term reliability in aggressive chemical environments is essential.

Manufacturing Standards – Tantalum Fasteners

All Tantalum fasteners are manufactured and tested to meet the following standards:

ASTM B365ASTM B708ASTM F560AMS 7845AMS 7846ASME B18.2.1ASME B18.2.2ASME B18.3ISO 4014/4017ISO 4762ISO 4026-4029ISO 4032DIN 931/933DIN 934DIN 912DIN 125NASMSANNACE MR0175EN 10204 3.1/3.2

We offer surface finishes: plain (as‑machined), chemically cleaned, passivated, and electropolished. Tantalum fasteners can be supplied with certified material traceability, dimensional inspection reports, and mechanical test certificates. Our manufacturing processes include CNC turning, thread rolling, and precision grinding to achieve tight tolerances. We specialize in custom configurations including non‑standard lengths, special head styles, and proprietary thread forms. Cleanroom packaging available for medical and semiconductor applications. All fasteners can be supplied with EN 10204 Type 3.1 or 3.2 certification. ISO 9001:2015 and AS9100D certified quality management system.

Why RAYCHIN LIMITED – The Tantalum Fastener Authority

Refractory metal expertise: Decades of experience with tantalum, niobium, tungsten, and molybdenum. We ensure precise chemistry and mechanical properties per ASTM, AMS, and customer specifications. In‑house PMI verifies chemistry of every heat. Our tantalum fasteners achieve full traceability and certified properties. Metallurgical engineering support for corrosion and high‑temperature applications.
Global certifications: ISO 9001, AS9100D, ISO 13485 (medical), PED, API Q1, NADCAP accredited processes. All fasteners supplied with EN 10204 3.1/3.2 certifications, material test reports, and NACE compliance when required. Complete in‑house manufacturing control from raw material to finished product.
Precision manufacturing: CNC machining and thread rolling ensure accurate fastener geometry per ASME, ISO, DIN, and NAS standards. Class 2A/3A/6g thread fit. 100% inspection available. Special tooling for tantalum's unique machining characteristics. In‑house passivation and cleaning capabilities for medical and semiconductor applications.
Custom solutions: Special head configurations, proprietary drives, non‑standard lengths, and tailored packaging. In‑house metallurgical laboratory and failure analysis capabilities. Application‑specific design consultation for corrosion and high‑temperature challenges. Flexible capacity for prototype and production volumes. Cleanroom wash and packaging available for sensitive applications.

Contact the Tantalum fastener experts

Request a quotation for Tantalum bolts, nuts, screws, washers, stud bolts, threaded rods – any standard (ASME, ISO, DIN, BS, NAS, MS, AN) – any condition (annealed, stress relieved), any quantity. Global delivery. Mechanical data in MPa/ksi available for all products. Medical‑grade tantalum per ASTM F560 available.

sales@ray-chin.com | +86 534 2166 566

Our team provides technical support in English, German, Mandarin, Japanese. Request a quote, sample requests, and material evaluation available.


RAYCHIN LIMITED – World‑class manufacturer of Tantalum fasteners: precision bolts, nuts, screws, washers, stud bolts, threaded rods – inch/metric series. Grades: Pure Tantalum (R05200, R05400, ASTM F560), Ta-2.5W (R05252), Ta-10W (R05255). Compliant with ASTM B365, B708, F560, ASME, SAE, API, NACE, ISO, DIN, KS, NAS, MS, AN. Chemical processing, aerospace, medical implants, semiconductor, nuclear, high‑temperature furnace industries. Full traceability, AMS certifications, NADCAP processing, NACE MR0175. Refractory metal fasteners with melting point 2996°C, exceptional corrosion resistance to all acids except HF, and complete biocompatibility. Precision manufacturing for critical fastening applications in extreme environments. All mechanical properties certified in MPa and ksi. Cleanroom packaging available for medical and semiconductor applications.

Head office: Taoyuan Road, East District, Pingyuan Economic Development Zone, Shandong, China

Tantalum fasteners USA · Tantalum bolts Europe · Tantalum nuts Germany · Tantalum screws UK · Tantalum washers Middle East · Tantalum stud bolts Asia · Tantalum threaded rods · R05200 fasteners · R05400 fasteners · ASTM F560 fasteners · refractory metal fasteners · corrosion resistant fasteners



Request A Quote! We'll respond as soon as possible(within 12 hours)

Submit
Related Products